Site Information For P-15341 STOPNGO EXPRESS

Basic
Business Address
1825 WICHMAN ST
WALTERBORO SC 29488
County
COLLETON
Phone
843-549-6217
Category
Retail Sales
Last Inspection
8/28/2023
Tank Owner Business Address
STOPNGO EXPRESS LLC
1825 WICHMAN ST
WALTERBORO SC 29488
Tank Owner Phone
843-290-3891
Land Owner Business Address
STOPNGO EXPRESS LLC
1825 WICHMAN ST
WALTERBORO SC 29488
Land Owner Phone
843-290-3891
Operator Business Address
STOPNGO EXPRESS LLC
1825 WICHMAN ST
WALTERBORO SC 29488
Operator Phone
843-290-3891
Tanks
3
Billable
3
Abandoned
0
Other
0
Financial Responsibility Show/hide financials
Financial Mechanism
Self Insurance 280.101
Expiration Date
8/17/2026
Tanks
Tank Num.
1
Constr. Date
1/26/1993
Class
P
Tank Const.
Steel Clad
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
6/8/1993
Status
Currently in Use
Tank Protect.
Fiberglass Coating
Tested
Pipe Protect.
Fiberglass
Tested
Notify
11/24/1992
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline Super/Prem
Overfill type
Ball Float Vent Valve
Verified
11/2/2020
Piping type
Pressure
Compliance
8/28/2023
Comp. Status
In Compliance
Age at Notification
0
Dist. to Well (feet)
101
Spill Prevention
1/26/1993
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
True
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
7/30/2015

Pipe Leak Det.

Mechanical Line Leak Detector
9/13/2022

Line Tightness Test
9/13/2022

Tank Num.
2
Constr. Date
1/26/1993
Class
P
Tank Const.
Steel Clad
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
6/8/1993
Status
Currently in Use
Tank Protect.
Fiberglass Coating
Tested
Pipe Protect.
Fiberglass
Tested
Notify
11/24/1992
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline E0
Overfill type
Ball Float Vent Valve
Verified
11/2/2020
Piping type
Pressure
Compliance
8/28/2023
Comp. Status
In Compliance
Age at Notification
0
Dist. to Well (feet)
101
Spill Prevention
1/26/1993
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
True
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
7/30/2015

Pipe Leak Det.

Mechanical Line Leak Detector
9/13/2022

Line Tightness Test
9/13/2022

Tank Num.
3
Constr. Date
1/26/1993
Class
P
Tank Const.
Steel Clad
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
6/8/1993
Status
Currently in Use
Tank Protect.
Fiberglass Coating
Tested
Pipe Protect.
Fiberglass
Tested
Notify
11/24/1992
Capacity
10000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline RUL
Overfill type
Ball Float Vent Valve
Verified
11/2/2020
Piping type
Pressure
Compliance
8/28/2023
Comp. Status
In Compliance
Age at Notification
0
Dist. to Well (feet)
101
Spill Prevention
1/26/1993
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
True
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
7/30/2015

Pipe Leak Det.

Mechanical Line Leak Detector
9/13/2022

Line Tightness Test
9/13/2022

Releases
No releases found for this site.