Site Information For P-06475 NEWBERRY ELECTRIC COOPERATIVE INC

Basic
Business Address
882 WILSON RD
NEWBERRY SC 29108-4618
County
NEWBERRY
Phone
803-276-1121
Category
Last Inspection
3/18/2025
Tank Owner Business Address
NEWBERRY ELECTRIC COOPERATIVE INC
882 WILSON RD
NEWBERRY SC 29108-4618
Tank Owner Phone
803-276-1121
Land Owner Business Address
NEWBERRY ELECTRIC COOPERATIVE INC
882 WILSON RD
NEWBERRY SC 29108-4618
Land Owner Phone
803-276-1121
Operator Business Address
WILLINGHAM, CARLA
882 WILSON RD
NEWBERRY SC 29108-0477
Operator Phone
803-276-1121
Tanks
4
Billable
1
Abandoned
3
Other
0
Financial Responsibility Show/hide financials
Financial Mechanism
Environmental Insurance
Expiration Date
4/15/2026
Tanks
Tank Num.
1
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
7/14/1987
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
7/14/1987
Capacity
2000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline
Overfill type
Verified
Piping type
Suction
Compliance
Comp. Status
Age at Notification
5
Dist. to Well (feet)
Spill Prevention
Left Gal.
Owner at ABD
NEWBERRY ELECTRIC COOPERATIVE INC
Last Use
Aband.
6/30/1998
Method
Removed
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.

Inv. Control w/Tank Tightness Testing

Tank Tightness Test

Pipe Leak Det.
Tank Num.
2
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
7/17/1987
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
7/14/1987
Capacity
2000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Diesel fuel
Overfill type
Verified
Piping type
Suction
Compliance
Comp. Status
Age at Notification
5
Dist. to Well (feet)
Spill Prevention
Left Gal.
Owner at ABD
NEWBERRY ELECTRIC COOPERATIVE INC
Last Use
Aband.
6/30/1998
Method
Removed
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.

Inv. Control w/Tank Tightness Testing

Tank Tightness Test

Pipe Leak Det.
Tank Num.
3
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
7/14/1987
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
7/14/1987
Capacity
550
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Diesel fuel
Overfill type
Verified
Piping type
Compliance
Comp. Status
Age at Notification
5
Dist. to Well (feet)
Spill Prevention
Left Gal.
Owner at ABD
NEWBERRY ELECTRIC COOPERATIVE INC
Last Use
Aband.
6/30/1998
Method
Removed
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.
Pipe Leak Det.
Tank Num.
4
Constr. Date
10/28/2002
Class
P
Tank Const.
Steel Clad
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
4/17/2003
Status
Currently in Use
Tank Protect.
Fiberglass Coating
Tested
Pipe Protect.
Fiberglass
Tested
Notify
10/24/2002
Capacity
15000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Multiple petroleum
Overfill type
Drop Tube Shut-off
Verified
3/21/2025
Piping type
Pressure
Compliance
3/28/2025
Comp. Status
In Compliance
Age at Notification
0
Dist. to Well (feet)
250
Spill Prevention
3/21/2025
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
4/11/2003

Automatic tank gauge

Pipe Leak Det.

Mechanical Line Leak Detector
1/3/2025

Line Tightness Test
1/3/2025

Line Tightness Test
1/3/2025

Mechanical Line Leak Detector
1/3/2025

Releases
Release No.
1
Reported
2/23/2009
Status
Product
Petroleum
Compliance Req?
True
NFA
4/15/2010
Fin Type
With insurance
RBCA / Score
5A - No pending threat, additional data / 0
Compliance Met
True
Confirmed
2/25/2009
Emergency Resp.
Superb Qualified
Compliance Date
2/27/2009
Cleanup Initiated
4/20/2009
Abatement Met
2/17/2009
Superb Determ. Date
Fin. Res. Mechanism
ENVINS
Cleanup Complete
4/15/2010
Transferred
Project Manager
SKOWRONEK, JOHN T
Cleanup > MCL
Source
UST
Responsible Party
NEWBERRY ELECTRIC COOPERATIVE INC
Release No.
0
Reported
8/2/2016
Status
Product
Compliance Req?
True
NFA
8/12/2016
Fin Type
RBCA / Score
/
Compliance Met
False
Confirmed
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
Transferred
Project Manager
PLACE, DENISE M
Cleanup > MCL
Source
UST
Responsible Party
NEWBERRY ELECTRIC COOPERATIVE INC
Release No.
0
Reported
8/27/1998
Status
Product
Compliance Req?
False
NFA
9/16/1998
Fin Type
RBCA / Score
/
Compliance Met
False
Confirmed
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
Transferred
Project Manager
GLYMPH-FANT, REBA M
Cleanup > MCL
Source
Responsible Party
Release No.
0
Reported
8/27/1998
Status
Product
Compliance Req?
False
NFA
9/16/1998
Fin Type
RBCA / Score
/
Compliance Met
False
Confirmed
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
Transferred
Project Manager
GLYMPH-FANT, REBA M
Cleanup > MCL
Source
Responsible Party