Site Information For R-05119 SCOTCHMAN 53

Basic
Business Address
3211 S KINGS HWY
MYRTLE BEACH SC 29577
County
HORRY
Phone
843-238-5612
Category
Retail Sales
Last Inspection
4/26/2024
Tank Owner Business Address
GPM SOUTHEAST LLC
8565 MAGELLAN PKWY STE 400
RICHMOND VA 23227
Tank Owner Phone
804-730-1568
Land Owner Business Address
MYRTLE BEACH FARMS COMPANY LLC
PO BOX 7277
MYRTLE BEACH SC 29572
Land Owner Phone
843-448-5123
Operator Business Address
GPM SOUTHEAST LLC
8565 MAGELLAN PKWY STE 400
RICHMOND VA 23227
Operator Phone
804-730-1568
Tanks
5
Billable
4
Abandoned
1
Other
0
Financial Responsibility Show/hide financials
Financial Mechanism
Surety Bond
Expiration Date
4/24/2025
Tanks
Tank Num.
1
Constr. Date
Class
R
Tank Const.
Steel
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
12/17/1998
Status
Currently in Use
Tank Protect.
Impressed Current
Tested
10/20/2021
Pipe Protect.
Fiberglass
Tested
10/20/2021
Notify
12/3/1985
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline RUL
Overfill type
Drop Tube Shut-off
Verified
12/17/1998
Piping type
Pressure
Compliance
4/26/2024
Comp. Status
In Compliance
Age at Notification
15
Dist. to Well (feet)
101
Spill Prevention
12/17/1998
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
4/1/2013

Pipe Leak Det.

Mechanical Line Leak Detector
3/5/2024

Line Tightness Test
3/5/2024

Tank Num.
2
Constr. Date
Class
R
Tank Const.
Steel
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
12/17/1998
Status
Currently in Use
Tank Protect.
Impressed Current
Tested
10/20/2021
Pipe Protect.
Fiberglass
Tested
10/20/2021
Notify
12/3/1985
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline RUL
Overfill type
Drop Tube Shut-off
Verified
12/17/1998
Piping type
Pressure
Compliance
4/26/2024
Comp. Status
In Compliance
Age at Notification
15
Dist. to Well (feet)
101
Spill Prevention
12/17/1998
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
4/1/2013

Pipe Leak Det.

Mechanical Line Leak Detector
3/5/2024

Line Tightness Test
3/5/2024

Tank Num.
3
Constr. Date
Class
R
Tank Const.
Steel
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
12/17/1998
Status
Currently in Use
Tank Protect.
Impressed Current
Tested
10/20/2021
Pipe Protect.
Fiberglass
Tested
10/20/2021
Notify
12/3/1985
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline Super/Prem
Overfill type
Drop Tube Shut-off
Verified
12/17/1998
Piping type
Pressure
Compliance
4/26/2024
Comp. Status
In Compliance
Age at Notification
10
Dist. to Well (feet)
101
Spill Prevention
12/17/1998
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
4/1/2013

Pipe Leak Det.

Mechanical Line Leak Detector
3/14/2024

Line Tightness Test
3/14/2024

Tank Num.
4
Constr. Date
Class
R
Tank Const.
Steel
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
12/17/1998
Status
Currently in Use
Tank Protect.
Impressed Current
Tested
10/20/2021
Pipe Protect.
Fiberglass
Tested
10/20/2021
Notify
12/3/1985
Capacity
8000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Diesel fuel
Overfill type
Drop Tube Shut-off
Verified
5/4/2022
Piping type
Pressure
Compliance
4/26/2024
Comp. Status
In Compliance
Age at Notification
10
Dist. to Well (feet)
101
Spill Prevention
12/17/1998
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge
4/1/2013

Pipe Leak Det.

Mechanical Line Leak Detector
3/5/2024

Line Tightness Test
3/5/2024

Tank Num.
5
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
8/14/1996
Capacity
1000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Diesel fuel
Overfill type
Verified
Piping type
Compliance
Comp. Status
Age at Notification
15
Dist. to Well (feet)
Spill Prevention
Left Gal.
50
Owner at ABD
JERRY COX COMPANY
Last Use
10/1/1988
Aband.
11/5/1998
Method
Removed
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.
Pipe Leak Det.
Releases
Release No.
1
Reported
12/10/1992
Status
Product
Compliance Req?
False
NFA
Fin Type
With SUPERB
RBCA / Score
3BF - GW < 15 feet in sand or gravel / 890
Compliance Met
False
Confirmed
1/21/1993
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
12/16/1997
Abatement Met
12/10/1992
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
Transferred
Project Manager
KELLETT, RYAN D
Cleanup > MCL
Source
UST
Responsible Party
JERRY COX COMPANY
Release No.
0
Reported
8/11/2020
Status
Product
Compliance Req?
True
NFA
8/21/2020
Fin Type
RBCA / Score
/
Compliance Met
False
Confirmed
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
Transferred
Project Manager
PLACE, DENISE M
Cleanup > MCL
Source
UST
Responsible Party
GPM SOUTHEAST LLC