Site Information For R-02477 COLLETON COUNTY SCHOOL BUS SHOP

Basic
Business Address
407 OLD AIR BASE RD
WALTERBORO SC 29488-3174
County
COLLETON
Phone
843-549-5549
Category
State Government
Last Inspection
4/9/2025
Tank Owner Business Address
SC DEPT OF EDUCATION
428 WHOLESALE LN
WEST COLUMBIA SC 29172
Tank Owner Phone
803-734-8252
Land Owner Business Address
SC DEPT OF EDUCATION
428 WHOLESALE LN
WEST COLUMBIA SC 29172
Land Owner Phone
803-734-8252
Operator Business Address



Operator Phone
Tanks
3
Billable
1
Abandoned
2
Other
0
Financial Responsibility Show/hide financials
Financial Mechanism
Exempt
Expiration Date
Tanks
Tank Num.
1
Constr. Date
Class
R
Tank Const.
Steel
Pipe Const.
Fiberglass reinforced plastic
Operat. Date
11/12/1985
Status
Currently in Use
Tank Protect.
Sacrificial Anode
Tested
5/1/2024
Pipe Protect.
Fiberglass
Tested
Notify
5/15/1987
Capacity
12000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Double wall
Variance
Product
Diesel fuel
Overfill type
Drop Tube Shut-off
Verified
5/2/2001
Piping type
Pressure
Compliance
4/9/2025
Comp. Status
In Compliance
Age at Notification
5
Dist. to Well (feet)
101
Spill Prevention
12/9/1998
Left Gal.
Owner at ABD
Last Use
Aband.
Method
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
True
Tank Leak Det.

Automatic tank gauge

Pipe Leak Det.

Mechanical Line Leak Detector
4/24/2024

Sump Sensor
4/17/2024

Line Tightness Test
4/24/2024

Tank Num.
2
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
5/15/1987
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
5/15/1987
Capacity
10000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Gasoline
Overfill type
Verified
Piping type
Suction
Compliance
Comp. Status
Age at Notification
25
Dist. to Well (feet)
Spill Prevention
Left Gal.
Owner at ABD
Last Use
Aband.
12/11/1998
Method
Fill with inert material
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.

Inv. Control w/Tank Tightness Testing

Tank Tightness Test

Pipe Leak Det.

Line Tightness Test

Tank Num.
4
Constr. Date
Class
N
Tank Const.
Steel
Pipe Const.
Steel
Operat. Date
5/15/1987
Status
Abandoned
Tank Protect.
Tested
Pipe Protect.
Tested
Notify
5/15/1987
Capacity
2000
Tank Cont. Meth.
Single wall
Pipe Cont. Meth.
Single wall
Variance
Product
Waste oil, burnt oil, used oil
Overfill type
Verified
Piping type
Compliance
Comp. Status
Age at Notification
5
Dist. to Well (feet)
Spill Prevention
Left Gal.
Owner at ABD
Last Use
Aband.
12/11/1998
Method
Fill with inert material
CAS No.
Chem.
Under Dispenser Cont.
False
Drop Tube
False
Tank Leak Det.

Manual Tank Gauging

Tank Tightness Test

Pipe Leak Det.
Releases
Release No.
1
Reported
12/16/1998
Status
Product
Compliance Req?
False
NFA
1/22/1999
Fin Type
Unknown
RBCA / Score
/
Compliance Met
False
Confirmed
1/14/1999
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
1/14/1999
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
1/22/1999
Transferred
Project Manager
GLYMPH-FANT, REBA M
Cleanup > MCL
Source
UST
Responsible Party
SC DEPT OF EDUCATION
Release No.
2
Reported
12/16/1998
Status
Product
Compliance Req?
False
NFA
1/22/1999
Fin Type
Unknown
RBCA / Score
/
Compliance Met
False
Confirmed
1/14/1999
Emergency Resp.
Superb Qualified
Compliance Date
Cleanup Initiated
1/14/1999
Abatement Met
Superb Determ. Date
Fin. Res. Mechanism
Cleanup Complete
1/22/1999
Transferred
Project Manager
GLYMPH-FANT, REBA M
Cleanup > MCL
Source
UST
Responsible Party
SC DEPT OF EDUCATION